- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bryan, Samuel A. (1)
-
Lines, Amanda M. (1)
-
Nelson, Gilbert L. (1)
-
Shafer, Jenifer (1)
-
Tse, Poki (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Optical spectroscopy is a powerful characterization tool with applications ranging from fundamental studies to real-time process monitoring. However, it can be difficult to apply to complex samples that contain interfering analytes which are common in processing streams. Multivariate (chemometric) analysis has been examined for providing selectivity and accuracy to the analysis of optical spectra and expanding its potential applications. Here we will discuss chemometric modeling with an in-depth comparison to more simplistic analysis approaches and outline how chemometric modeling works while exploring the limits on modeling accuracy. Understanding the limitations of the chemometric model can provide better analytical assessment regarding the accuracy and precision of the analytical result. This will be explored in the context of UV–Vis absorbance of neodymium (Nd 3+ ) in the presence of interferents, erbium (Er 3+ ) and copper (Cu 2+ ) under conditions simulating the liquid–liquid extraction approach used to recycle plutonium (Pu) and uranium (U) in used nuclear fuel worldwide. The selected chemometric model, partial least squares regression, accurately quantifies Nd 3+ with a low percentage error in the presence of interfering analytes and even under conditions that the training set does not describe.more » « less
An official website of the United States government
